Showing results: 31 - 45 of 156 items found.
-
MAC-01, -02, -03 -
Compact Power Company
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
MZC-310S -
Sonel S.A.
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
CZ20054 -
Aegis Pty. Ltd.
Australian and New Zealand standards mandate testing of fault loop impedance on circuits not protected by RCD's, both at installation and after maintenance. The CZ20054 Loop Impedance Tester conducts earth fault loop impedance and prospective short circuit current (PSC) tests. The Aegis Loop Impedance Tester takes the confusion out of loop/psc testing by providing an automatic wiring check upon connection and single button operation.
-
MS-420 -
Martel Calibrators
The Loop Calibrator is a multi-purpose process loop tool that offers high accuracy in an ultra-small, rugged package. A single pushbutton selects one of five current outputs (4, 8, 12, 16 or 20 mA), which can drive up to 300 Ohms, or can act as a 2-wire simulator with an external loop power supply of up to 30 VDC.
-
4-20mA -
Riverhawk Company
Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.
-
Shanghai Powoo Industry Develop Group Limited
ATS can provide double loop current sampling and power supply for measuring unit of static meter. When load voltage, static meter can in normal condition without single-channel current.
-
Promis 10 -
IRIS Instruments
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
CYHCT-L20K -
ChenYang Technologies GmbH & Co. KG
The sensor CYHCT-L20K is based on open loop principle and designed with a high galvanic isolationbetween primary conductor and secondary circuit. It can be used for measurement of DC current, DCpulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
AMZC-304 -
Amperis sl
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Weshine Electric Manufacturing Co., Ltd
The loop resistance tester is used to test the conductive loop resistance of various switchgear, and the test current shall not be less than 100A. Due to the oxidation of the contact surface, poor contact tightening and other reasons, the contact resistance increases. When a large current flows, the temperature of the contact point increases, which further accelerates the oxidation of the contact surface and further increases the contact resistance.
-
-
SY020 -
Synectic Electronics
The SY020 Pulse Rate Converter can be linked to any frequency generating device e.g. flow meters, which gives TTL, pulse Reed switch or coil output, converting the frequency to an analogue signal. This can be 4-20mA loop current or a voltage output. The 4-20mA version unit is loop powered.
-
CYHCT-C2TC -
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Yangzhou Power Electric Co., Ltd
High current test systems are used to test the thermal stability of equipment and components. The test system induces a current in the test object causing it to heat up.The system can perform the heat cycle testing for power cables type test and pre-qualification test according to IEC 60840, and IEC 62067 etc. Based on pre-qualification test needs, test system is divided into two parts: test sample loop and simulation temperature loop.
-
72-1020 -
Tenma